Kitchen extraction
Kitchen extraction, designed to DW/172.
Canopies, ductwork, fans and odour control designed, fabricated and installed by one team, with the calculations and drawings your landlord, insurer and local authority ask for.
The canopy is the part you see. The system behind it decides whether the kitchen is comfortable, safe and allowed to open.
How the air moves
From the cooking line to the roof.
Canopy size and air volumes come from the DW/172 calculation. What is needed at the discharge point is set by the EMAQ+ assessment.
What we design and build
The whole system, not just the canopy.
Extraction canopies
Wall, island and condensation canopies in stainless steel, sized to overhang the cooking line and fitted with baffle grease filters.
Supply and make-up air
Fresh air brought in through the canopy or the room and balanced against the extract, so the kitchen stays comfortable and cooking smells stay in it.
Ductwork
Kitchen extract ductwork fabricated in our workshop and installed with access doors for cleaning, on a route agreed with the building.
Fans and controls
Fans selected for the real resistance of the system, with speed control and an interlock to the gas supply.
Odour and noise control
Filtration, electrostatic precipitation, UV or carbon, and attenuation, chosen from an EMAQ+ assessment of the site.
Fire suppression
Canopy fire suppression co-ordinated with the cooking line, the extract and the gas shut-off.
DW/172
Designed to the specification inspectors use.
DW/172 is the Specification for Kitchen Ventilation Systems published by BESA, the Building Engineering Services Association. It is the document designers, insurers and environmental health officers refer to. The second edition was published in 2018 and has been amended since; we design to the current version.
What a DW/172 design covers
- Extract rates calculated from the appliances under the canopy
- Canopy size, height and overhang set against the cooking line
- Grease filtration matched to the type of cooking
- Make-up air and the balance between supply and extract
- Duct sizes, air velocities and access for cleaning
- Materials and construction of canopies and ductwork
What an EMAQ+ assessment covers
- How well the discharge disperses
- How close the nearest neighbours are
- The size of the kitchen
- The type of cooking and how much grease and odour it produces
- The level of odour control that follows: low, high or very high
- Fan and plant noise at the nearest neighbour
EMAQ+
Odour and noise, answered before planning asks.
Where a kitchen exhaust discharges near neighbours, the local authority will usually ask how odour and noise are controlled. The reference is the EMAQ+ guidance, Control of Odour and Noise from Commercial Kitchen Exhaust Systems, which updated the withdrawn DEFRA guidance of 2005.
The assessment scores the site and the total sets the level of odour control. We carry out the assessment, show the scoring and specify plant to match.
How it runs
From survey to handover pack.
01
Survey
We measure the kitchen, the route out of the building and the discharge point, and record what is already there.
02
Calculate and draw
Extract and supply rates to DW/172, the EMAQ+ assessment where it is needed, and drawings you can submit.
04
Install and commission
Our engineers fit the system, prove the gas interlock and measure the air volumes against the design.
05
Hand over
Calculations, drawings, commissioning figures and a cleaning schedule, in one pack.
Questions
Kitchen extraction, answered.
Does every commercial kitchen need extraction?
Any kitchen with appliances that give off heat, steam, grease or combustion products needs mechanical ventilation to remove them. Where the appliances are gas, the ventilation is interlocked with the gas supply so the gas cannot be used unless the ventilation is running.
What is DW/172?
DW/172 is the BESA Specification for Kitchen Ventilation Systems. It sets out how canopies, extract and supply air, grease filtration and ductwork for commercial kitchens should be designed and built, and it is the reference most landlords, insurers and local authorities ask designs to follow.
When is an EMAQ+ odour assessment needed?
Usually when planning permission or a change of use is involved, or when a landlord or the local authority asks for one. It is requested most often where the exhaust discharges close to homes.
How often does a kitchen extraction system need cleaning?
It depends on how hard the kitchen works. TR19 Grease, the BESA specification for grease in kitchen extract systems, sets cleaning intervals by hours of use. We build in access doors and provide a schedule so the cleaning contractor can do the job properly.
Can you work with an existing canopy or ductwork?
Often, yes. We survey what is there, check it against the cooking line you plan to run, and tell you plainly what can stay, what needs altering and what has to be replaced.
Let's talk
Planning a kitchen that needs extraction?
Send us a floor plan, a sketch on a napkin or just a rough idea. We’ll come back with honest advice, a site visit and a clear quote.